ONLINE UPS E² Series 1KVA 24VDC-IB
Online double-conversion UPS (1KVA) that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Available at Nice Power System, Delhi NCR.
Save ₹7,091
Online (double-conversion) UPS for equipment that can't tolerate even a momentary dip — Microtek's E², iMAXX and MAX+ series from 1kVA up to 7.5kVA and beyond. The load always runs off a rebuilt, regulated waveform with zero transfer time, protecting servers, networking and CCTV racks, billing/POS systems and medical or lab equipment. We size the unit and external battery bank, install on-site, and offer AMC across Delhi NCR.
Home installation · On-site service & AMC across Delhi NCR

Online double-conversion UPS (1KVA) that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Available at Nice Power System, Delhi NCR.
Save ₹7,091

Buy the ON LINE UPS 5.5KVA, 1ph: 1ph, 192V iMAXX SERIES — a 5.5 KVA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Home installation & service across Delhi NCR.
Save ₹20,591

7.5 KVA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Genuine stock from Nice Power System, Delhi NCR.
Save ₹14,991

6000VA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Genuine stock from Nice Power System, Delhi NCR.
Save ₹23,891

10000VA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Genuine stock from Nice Power System, Delhi NCR.
Save ₹17,191

Buy the ON LINE UPS 10KVA, 1ph: 1ph, 192V iMAXX SERIES — a 10.0 KVA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Home installation & service across Delhi NCR.
Save ₹12,991

Online double-conversion UPS (1 KVA) that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Available at Nice Power System, Delhi NCR.
Save ₹5,991

Online double-conversion UPS (1 KVA) that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Available at Nice Power System, Delhi NCR.
Save ₹5,391

2 KVA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Genuine stock from Nice Power System, Delhi NCR.
Save ₹9,191

Online double-conversion UPS (2 KVA) that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Available at Nice Power System, Delhi NCR.
Save ₹7,591

3 KVA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Genuine stock from Nice Power System, Delhi NCR.
Save ₹10,391

Online double-conversion UPS (3000VA) that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Available at Nice Power System, Delhi NCR.
Save ₹57,391

Buy the ONLINE UPS MAX+ 3KVA 1PH:1PH 72V — a 3 KVA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Home installation & service across Delhi NCR.
Save ₹9,591

5000VA online double-conversion UPS that protects servers, networking and other critical equipment with clean, zero-transfer-time power. Genuine stock from Nice Power System, Delhi NCR.
Save ₹61,691
These three get sold interchangeably and they are not interchangeable. A home inverter is a backup device: it sits idle, senses a cut, and switches over in a few milliseconds. That gap is invisible to a fan or a light and fatal to nothing in a house — but a server mid-write, a CCTV NVR, or a diagnostic machine can see it.
A line-interactive UPS narrows the gap and adds automatic voltage regulation, so mild high or low mains is corrected without touching the battery. It suits a desktop, a billing counter, a router or a DVR.
An online (double-conversion) UPS never switches at all. Incoming AC is rectified to DC and rebuilt into a fresh sine wave continuously, so the load is permanently isolated from whatever the grid is doing — surges, sags, frequency drift, harmonics. Transfer time is zero because there is no transfer. That is why it is the only correct answer for a server room, a rack of networking gear, a POS estate, or lab and medical equipment.
Size on connected load in VA, then leave headroom. Add up the nameplate VA of everything the UPS will carry, then add roughly 25% for growth and inrush — motors, laser printers and older switch-mode supplies draw far more at startup than they do running.
Two habits ruin installations here. The first is sizing to today's rack and none of next year's. The second is sizing to watts and quoting VA, or the reverse: a unit quoted as 5kVA is typically around 4kW, and if your load is genuinely 5kW that unit is already over its limit before a single machine is added.
Voltage matters as much as capacity, because it sets the battery bank. A 1kVA unit on a 36V bus and a 2kVA on 72V need different numbers of batteries wired in series, and that is usually the larger part of the bill.
The UPS determines how much load you can carry; the battery bank determines how long. Internal batteries typically give minutes — deliberately, because the design intent is a safe shutdown or a bridge to a generator starting, not riding out a Delhi evening cut.
If you need genuine hours, you are buying an external battery bank sized to a target runtime, and the space, ventilation and floor loading that come with it. Tell us the runtime you actually need and we will size the bank rather than sell you a bigger UPS that still dies in eight minutes.
Ask what happens on generator power: some generators produce a waveform and frequency wobble that an online UPS will reject, dropping to battery and never recharging. Compatibility is a specification question, not a hope.
Ask about service response, not just warranty length. A UPS protecting revenue is only as good as the time it takes to get an engineer to it — which is the argument for buying locally rather than from a marketplace listing with no Delhi presence.
And ask to see the load calculation written down. Any supplier who quotes a capacity without asking what you are plugging in is guessing.
Free, no-jargon advice from our Ashok Vihar shop to help you choose.
An online UPS continuously rebuilds the output, so there's no changeover gap and the power is perfectly clean — essential for servers and sensitive electronics. A home inverter has a few-millisecond switch and is meant for household backup, not critical loads.
Size it to the connected load in VA, with margin. A few PCs and network gear are usually covered by a 1–2kVA unit (e.g. the E² 1kVA); a server room or several racks may need 5–7.5kVA (iMAXX / MAX+ series). We'll total your load and specify it.
Internal batteries give a few minutes — enough for a safe shutdown or to bridge to a generator. For longer runtime we configure an external battery bank sized to your target and install it on-site in Delhi NCR.